Flaw Detector

Olympus Omniscan MX 16:128 Phased Array Flaw Detector

Sale Olympus Omniscan MX 16:128 Phased Array Ultrasonic Flaw Detector. Includes Main Unit, 16:128 Phased Array Module, probe, AC Adapter, and all else pictured.

$6,000
Used Condition

Sale Olympus Omniscan MX 16:128 Phased Array Ultrasonic Flaw Detector 16:128 Module, Windows CE 5.0 operating system. Tested in good working and cosmetic condition.

Package includes:

  • Olympus Omniscan MX 16:128 unit
  • 16:128 Phased Array Module
  • Probe
  • AC Adapter
  • Hard case
  • 14 Day return

OmniScan MX general specifications:

Housing

Size 321 x 209 x 125 mm (12.6 x 8.2 x 5 in.)
Weight 2.8 kg (6.2 lb) [no module and one battery]
4.6 kg (10.1 lb) [module and one battery]

Environmental conditions

Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature −20 °C to 60 °C (−4 °F to 140 °F)
Humidity Max. 85 % RH at 40 °C (104 °F) noncondensing
Altitude Up to 2000 m
Outdoor use With batteries only
Pollution level 2

Batteries

Battery model OMNI-A-BATT (U8760010)
Battery type Smart lithium-ion batteries
Number of batteries 1 or 2
Battery charge time <3.5 hours using the internal battery charger or an optional battery charger
Battery life Minimum 6 hours with two batteries; minimum 3 hours per battery under normal operating conditions

External DC supply

DC-IN voltage 15 VDC to 18 VDC (min. 50 W)
Connector Circular, 2.5 mm pin diameter, centerpositive
Display
Display size (diagonal) 213 mm (8.4 in.)
Resolution 800 x 600 pixels
Number of colors 16 million
Type TFT LCD visible from any angle
Data storage
Storage devices Optional CompactFlash card, most standard USB storage devices, or through optional fast Ethernet
Maximum data file size Limited to available internal flash memory: 180 MB (or 300 MB optional)
I/O ports
USB ports 3x USB 1.1 ports, rated 500 mA output current
Speaker out Yes, mono, minimum of 8 Ω total impedance
Video output Video out (SVGA)
Video input Video input (NTSC/PAL)
Ethernet 10/100 Mbps (megabits per second)
I/O lines
Encoder 2-axis encoder line (quadrature or clock/direction)
Digital input 2 digital inputs TTL, 5 V
Digital output 4 digital outputs TTL, 5 V, 15 mA maximum per output
Remote communication Remote communication RS-232 or RS-485
Acquisition on/off switch Remote acquisition enable TTL, 5 V
Power output line 5 V nominal, 500 mA nominal power output line (short-circuit protected)
Alarms 3 TTL, 5 V, 15 mA maximum
Analog output 2 analog outputs (12-bit resolution) ±5 V nominal in 10 kΩ, 10 mA maximum per output
Pace input 5 V, TTL pace input
Alarms
Number of alarm zones 3
Conditions Any logical combination of gates
Analog outputs 2